There are generally five main types of fire extinguishers out there; carbon dioxide CO2, dry powder, water, foam, and wet chemical extinguishers. It’s vital to choose the most suitable type for your business needs to meet the safety rules and regulations. Besides selecting the right kind, make sure that you’ve got a fire extinguisher of the right size and weight.
What Is a CO2 Type Fire Extinguisher?
CO2 type fire extinguishers are usually utilized for protection against electrical fire hazards. These are the leading fire extinguishers used in computer server rooms. They can also be used to put out Class B type fire risks, including flammable liquids like paints and petrochemicals. It comes with black label color identification purposes.
What Is CO2 Fire Extinguisher Used For?
One of the most popular choices for fire extinguishers is that the CO2 type can be used to get effective results on electrical fires and class B & C fires. These can be utilized on electrical equipment related hazards irrespective of high low voltage. CO2 fire extinguishers are extremely effective against liquid flammables like propane, solvents, butane, and paint petrol.
- Flammable liquids like paint and petrol Electrical fires
- When Should You Not Use A CO2 Fire Extinguisher?
Carbon dioxide CO2-based extinguishers should not be used for mitigating the following fire risks:
- All Class A fires or ordinary combustibles
- Confined spaces in which you could inhale fumes
- Kitchen fires, particularly chip-pan fires
- Combustible substances like wood, paper or textiles
- Flammable metal pieces
How CO2 Fire Extinguishers Operate
CO2 fire extinguishers put out fires by displacing the much-needed oxygen for the fire to keep burning. Carbon dioxide is extremely cold as it comes out of the extinguisher, which results in cooling down the fuel. These types of extinguishers consist of CO2 in a liquid form. After letting the extinguisher off, the liquid carbon dioxide gets released into the air neutralizing the oxygen necessary for fire.
As fire needs oxygen to feed on, extinguisher disables the fire’s ability to spread by nullifying it. CO2-based fire extinguishers are an extremely effective way of putting out fires – they also stop the fire from happening again due to lack of oxygen and the freezing temperature of carbon dioxide when released from the extinguisher.
How To Inspect A CO2 Fire Extinguisher
All kinds of fire extinguishers, including CO2 type, must be inspected regularly at least once in a month. The following are some of the steps you’ve to follow to inspect your CO2 fire extinguisher properly:
Locate your apparatus first – you’ve to know the exact spot where your fire extinguisher is located. Although it might seem quite an obvious thing, you must be completely aware of its whereabouts. It’s imperative to keep it an easily accessible place; a spot where you can reach your equipment if there’s a fire-emergency
Verify your extinguisher’s class – check its labeling to ensure that it’s effective against fire-hazards that could happen in your premises
Examine the plastic seal thoroughly – each fire extinguisher comes with a pre-installed plastic seal that holds the safety place in place. Report any devices with broken or missing seals to your local fire department immediately
Weight your cylinder regularly – carbon dioxide extinguishers are increasingly pressured and miss gauges, which are part of other types of fire extinguishers. That’s why it’s highly significant to weigh them regularly to check how much CO2 is inside. The majority of the CO2 fire extinguishers are labeled for respective weights. Some of the sizes are CO2 fire extinguishers in 5kg, 2kg, 30kg, and 45kg
Inspect the nameplate, pin, and nozzle carefully – don’t forget to check these vital components for any possible damage
CO2 Fire Extinguisher Price
The prices of CO2 fire extinguishers vary from one manufacturer to another. Many factors come into play when deciding the exact cost of a carbon dioxide extinguishers, including the following:
- The capacity of the cylinder
- Safety valve
- Operating temperature
- Maximum allowable pressure
- Test pressure
- Equipment Volume
- Cylinder height, diameter, neck thread, and material
- Valve material
- Gross weight and dimensions
- Paint finish
- Packaging details
- Different manufacturers provide different price quotes for their CO2 extinguishers based on the materials used in them.
Final Thoughts
CO2 type fire extinguishers are highly useful tools for dealing with extraordinary fire-related hazards at your home or business. Wherever you utilize this equipment, make sure you follow the guidelines given above and get adequate training before trying to use one in case of a fire emergency
About Capital Solutions
Capital Solutions specializes in providing high-quality CO2 fire extinguishers in different sizes ranging from 5kg to 45kg across Pakistan. For further information, you may visit our website, or you can call us for personalized care. For CO2 extinguishers in various sizes in Pakistan, Contact us at 051-4446640